ライフ、健康

元気で幸せで暮らすため いい生活習慣を身に付けまましょう

RFID Android Handheld POS Terminal Acquisition Equipment Makes Inventory No Longer Difficult!

2020-04-08 21:08:04 | 高齢社会
With the rapid advancement of intelligent production, various links are becoming more demanding, and production and sales are increasingly focusing on automation and asset management. RFID technology has become one of the important builders of intelligence, and has contributed greatly to rapid inventory.

UHF android handheld pos terminal collection will change the traditional manual inventory counting of the equipment. Due to the tedious operation of the inventory, it is easy to make mistakes, and the labor efficiency is low. RFID handheld terminal acquisition equipment easily solves these problems, makes the quick inventory work easily completed, the accuracy rate is very high, so that inventory is no longer difficult to say!

Taking asset management as an example, the company has a large number of production equipment and inventory products, high density, and high operating temperature of some equipment. If it is managed based on traditional barcodes or QR codes, it will face the following problems:

1. Bar code or two-dimensional code labels are easily damaged, and the replacement cost is high;

2. Can't scan all QR codes in one area at a time in batches, the operation efficiency is low.

android-handheld-pos-terminal

In contrast, RFID receivers have a long life and high tolerance to harsh environments, and the handheld mobile RF scanner can scan and accept data from multiple receivers at once, solving the above problems. Therefore, replacing the QR code with the RFID solution has become a new choice for enterprises to solve problems such as production automation and asset management.

Read the information of the goods through the UHF RFID android handheld pos terminal collection device and compare it with the goods of the system, you can easily check the quantity, type, warranty period and other information of the goods. Compared with the traditional inventory work, it not only saves a lot of human resources and reduces labor costs, but also improves work efficiency and accuracy, and reduces business losses. Through the management system to adjust the cargo position, no manual adjustment is required, which is more intelligent and accurate.

UHF RFID handheld terminal acquisition equipment is also called PDA. Due to its lightweight and industrial design, it is suitable for mobile and inconvenient occasions. Through RFID read-write function, the use of radio frequency identification technology for data non-contact, automatic collection, long-distance identification, RFID electronic tags can be read. PDA is widely used in logistics warehouse distribution management; retail store invoicing; manufacturing workshop parts, semi-finished products, finished product management; fixed asset management; outdoor equipment mobile inspection, patrol and other asset inventory management.

How to solve the problems of wear and corrosion of pulverized fuel boiler induced draft fan?

2020-04-08 21:06:39 | 高齢社会
Pulverized fuel boiler induced draft fan is a driven fluid machine that relies on the mechanical energy input by the motor to increase the gas pressure and exhaust the gas. Induced draft fans for large-scale power station boilers are generally fixed-blade or adjustable-blade axial flow fans. The lifting force generated by the impeller rotation is used to introduce the flue gas in the boiler into the desulfurization island or chimney in the axial direction.

The normal operation of the induced draft fan can ensure the thermal circulation in the boiler and ensure the stable production and supply of electricity. However, due to the special working environment of the induced draft fan, frequent failures occur during continuous use, which seriously affects the normal operation of the power plant.

Boiler induced draft blade wear and corrosion are a common problem, so what causes this problem to occur frequently?
1. Because the blade is hollow, some dust in the air will enter the blade when the wind enters and exits, and the solid objects in the return stroke will cause friction with the blade and cause the blade to wear.
Or because the dust removal device of the equipment is not cleaned in time, the dust enters the blade, and its function is similar to that of a file, which exacerbates the wear of the blade. In the past, the blade edge will be worn until it breaks.

2. Thermal electric boiler flue gas desulfurization technology uses the flue gas to mix the dust in the flue gas and harmful gases such as sulfur dioxide and carbon monoxide into the water through the aqueous solution or water curtain to achieve the purpose of desulfurization. The induced draft fan is generally installed at the back of the desulfurization and dust removal equipment. When the induced draft fan sends air, the sulfides and carbides in the dust will corrode the blades. In addition, the sulfur dioxide gas generated by the boiler combustion will cause different degrees of corrosion to the blades.

Faced with the problems of wear and corrosion of the boiler induced draft fan, how should we solve it?
The pulverized fuel boiler induced draft fan can be coated with an anticorrosive coating, which is a highly functional two-component thermosetting polymer coating. The coating formed after curing exhibits superior corrosion resistance. The coating molecular cross-linking is mainly based on the ether bond method (COC). The ether bond is a very strong chemical bond. Compared with epoxy resins, it does not contain hydroxyl groups. Compared with vinyl esters, it has no ester bonds, so it can withstand hydrolysis. And acid attack.

Anticorrosive coatings have significant features and benefits, including:
• Strong corrosion resistance, can withstand many corrosive chemicals, including strong acids, strong bases, gases, solvents and oxidants
• Excellent abrasion resistance
• Excellent adhesion and adhesion to metal substrates, composite materials and concrete
• Excellent flexibility
• High temperature, cold and heat resistance
• Resistant to water clearing

The excellent performance of the anticorrosive coating has made it a good application in the wear and corrosion protection of boiler induced draft fans.

Tail Butt - Piglet Gas Tail Docker

2020-04-08 21:05:51 | 高齢社会
For various reasons, pigs may bite each other's tails. This can lead to infections, spinal abscesses, severe pain, la lines and car body condemnation.If other management methods are not working, your veterinarian may recommend docking the tail to prevent tail biting. If tail docking is recommended, its necessity must be reviewed regularly (quarterly) as part of the department's veterinary health plan, and a concerted effort must be made to provide actionable material in all pens.

Tail docking equipment
• Ensure that the operator is familiar with the manufacturer's instructions.
• Check if the blade is clean and heated properly.
• Check if the battery is charged or has a sufficient gas tank.
• Faders must be dedicated to this process and not for cutting teeth, make sure they are sharp and clean.
• Pack equipment and materials in a belt bag or transport container before entering the farrowing area to ensure that the operator is separated from the sow.

Work outline
• Don't try to cut like scissors, but let the heat burn, and fix the equipment container in a safe and convenient place in the first delivery room or shed.
• Collect all piglets into a storage container, make sure the cautery blade is fully heated, then pick up the piglets on the hind legs above the hock or around the hips, keeping the tail stable during operation.
• Gently squeeze the piglet gas tail docker to remove the proper length of the tail. Clippers should be disinfected in time when used on different piglets.
• Regularly inspect and remove debris from the cautery blades and rails using a designated wire brush.
• Make sure all tails are evenly docked in one unit, so it's useful to have a mark on the fader to indicate the standard docking length of the device.
• Record the incidence of tail bites in a timely manner so that there is the latest evidence that the docking needs to continue. If tail biting continues in docked pigtails, other suggestions and measures should be sought to help resolve the issue.