gooブログはじめました!

写真付きで日記や趣味を書くならgooブログ

PTO Configuration Test: Remote Throttle (using Caterpillar ET Software)

2023-02-20 21:13:45 | 日記
1). Use CAT ET to Check the Programming of the Parameter Dedicated PTO Parameters.
→Connect CAT ET to the data link connector.
→Access the Dedicated PTO Parameters on CAT ET. Note the programming of the parameter PTO Configuration (Remote Throttle).
 
2). Check the Circuit for the PTO On/Off Switch.
→Activate the PTO operation.
→Access the CAT ET Status screens that display the following Status parameters.
  • PTO Config (Remote Throttle)
  • PTO On/Off Switch - J1/P1:56
→Verify that each of the interlocks for the PTO are set. Then, while the CAT ET Status screen is being monitored, move the PTO On/Off Switch to the ON and OFF position.
 
3). A Remote Accelerator Pedal Position Sensor is connected to ECM P1/J1-68 (Input 8) when the PTO
Configuration is programmed to Remote Throttle.
→Monitor the Status of PTO Throttle Position and PTO Throttle Sensor Duty Cycle and output to controls the Engine Speed
 
→Or you can manually measure the PTO Remote Throttle signal using the Multimeter (DC Volts and Duty Cycle).
 
4). Monitor using the Real Time Graphing while simulate the PTO Configuration Test (Remote Throttle). 
 
When the PTO Configuration is programmed to Remote Switches or to Remote Throttle and the PTO On/Off Switch is On, the following circuits are ignored:
• Service Brake Pedal Position Switch 1
• Service Brake Pedal Position Switch 2
• Clutch Pedal Position Switch
• Neutral Switch
• Accelerator Pedal Position Sensor
• Cruise Control Set/Resume Switch that is located in the Cab.
 
A friend told me that I can find the answer here, I think I can try it, https://www.obd2.ltd/

 


How to Set Up Caterpillar ET Software SIS and CBT Offline Setup

2023-02-11 11:50:10 | 日記

How to Settings SIS and CBT Offline (using DVD or Virtual Drive) on Caterpillar ET Software?

SIS – Service Information System
CBT – Component Based Troubleshooting

CBT (Component Based Troubleshooting) DVD can now be downloaded
directly from Caterpillar. The application provides access to
troubleshooting information in a disconnected environment when used with
any current SIS DVD subscription. To download, go to
https://dealer.cat.com/stw and select CBT (Component Based
Troubleshooting) Download.

Having CBT DVD and a SIS DVD subscription installed on your PC allows
the Troubleshoot Code and Troubleshoot Symptom buttons in Cat ET to
function correctly when you are disconnected from the web.

1). Open CAT ET Software: select Utilities – Preferences – Modify…

2). Open CBT and SIS menu, and settings: CBT Data Source (to DVD), and SIS Data Source (to DVD), then click OK.


3). Using Cat ET Trainer, then try to check the Troubleshoot Code/
Troubleshoot Symptom from Active Diagnostic/Event Codes. Read More:
TRAINER on Caterpillar ET Software.

4). Select menu: Diagnostics – Events – Active Events.

5). Click on Troubleshoot Code or Troubleshoot Symptom.

6). CBT Messages: DVD not found (Please Insert the SIS DVD), or mount image to Virtual Drive – DVDD0003. Once done, click OK.


7). It will automatically displays the CBT documents based on the Active Code (Codes + Engine).